Required Septic System Setbacks
            
    
    
    
    	
      
  
Table 1 - OAR 340-71-220 Minimum Separation Distances
| Items Requiring Setback | 
From Sewage Disposal Area Including Replacement Area | 
From Septic Tank and Other Treatment Units, Effluent Sewer and Distribution Units | 
- Groundwater Supplies
 
 
 | 
100' | 
50' | 
- Temporarily Abandoned Wells
 
 
 | 
100' | 
50' | 
- Springs:
 
 
- Upgradient:
 
- Downgradient:
 
 
 
 | 
 
 50' 
100' 
 | 
 
 50' 
50' 
 | 
- Surface Public Waters:
 
 
- Year Round (Perennial)
 
- Seasonal (Intermittent)
 
 
 
 | 
 
 100' 
50' 
 | 
 
 50' 
50' 
 | 
- Intermittent Streams:
 
 
- Piped (Watertight not less than 25' from any part of the on-site system):
 
- Unpiped:
 
 
 
 | 
 
   
20' 
50' 
 | 
 
   
20' 
50' 
 | 
- Groundwater Interceptors (GWI)
 
 
- On a Slope of 3% or Less:
 
- On a Slope Greater than 3%:
 
 
- Upgradient:
 
- Downgradient:
 
 
 
 
 | 
 
   
20' 
			  
  
10' 
  
50' 
 | 
 
   
10' 
			  
  
5' 
  
10' 
 | 
- Irrigation Canals:
 
 
- Lined (Watertight Canal):
 
- Unlined:
 
 
- Upgradient:
 
- Downgradient:
 
 
 
 
 | 
 
   
25' 
			  
  
25' 
  
50' 
 | 
 
   
25' 
			  
  
25' 
  
50' 
 | 
- Cuts Manmade in Excess of 30 Inches (Top of Downslope Cut):
 
 
- Which Intersect Layers that Limit Effective Soil Depth Within 48 Inches of Surface:
 
- Which do not Intersect Layers that Limit Effective Soil Depth:
 
 
 
 | 
 
   
			  
  
			50' 
25' 
 | 
 
   
			  
  
			25' 
10' 
 | 
- Escarpments:
 
 
- Which Intersect Layers that Limit Effective Soil Depth:
 
- Which do not Intersect Layers that Limit Effective Soil Depth:
 
 
 
 | 
 
   
			50' 
25' 
 | 
 
   
			10' 
10' 
 | 
- Property Lines:
 
 
 | 
10' | 
5' | 
- Water Lines:
 
 
 | 
10' | 
10' | 
- Foundation Lines of any Building or Structure:
 
 
 | 
10' | 
5' | 
- Underground Utilities:
 
 
 | 
10' | 
-- | 
This does not prevent stream crossing of pressure sewer effluent sewers.